Precision Kinematic Viscosity Bath: 403/404/405 Series
The 403-262 is a precision constant-temperature bath designed and manufactured in conformity with JIS K2283, ASTM D445/D446, and ISO 3104/3105 for kinematic viscosity determination. It is the successor to the long-serving 403-162 model, redesigned for a smaller footprint, lower power consumption, and improved safety.

Manufacturer: Rigo — Japan
Overview
The 403-262 is a precision constant-temperature bath designed and manufactured in conformity with JIS K2283, ASTM D445/D446, and ISO 3104/3105 for kinematic viscosity determination. It is the successor to the long-serving 403-162 model, redesigned for a smaller footprint, lower power consumption, and improved safety. The bath's temperature control uses a PID control method that reliably maintains the set temperature to within ±0.01°C. High-temperature testing is covered by the companion 404 series, and low-temperature testing exclusively by the 405 series, so the three series together span the full temperature range needed for kinematic viscosity work.
PID Temperature Control
The bath's PID-based temperature controller maintains the set point to within ±0.01°C, which supports the tight repeatability requirements of JIS K2283, ASTM D445/D446, and ISO 3104/3105. Consistent, stable bath temperature is essential for accurate kinematic viscosity results, since even small temperature deviations translate directly into measurement error.
Compact, Safer Successor Design
The 403-262 succeeds the earlier 403-162 model with a smaller footprint, reduced power consumption, and improved safety features. This makes it easier to accommodate in laboratories with limited bench space while retaining the same measurement performance.
Medium, High, and Low-Temperature Coverage
The 403 series is intended for medium-temperature kinematic viscosity testing, while the 404 series is suited to high-temperature applications. The 405 series is dedicated exclusively to low-temperature testing, completing the temperature range covered by the three series.
Common Specifications
| Specification | 403/404/405 Series |
|---|---|
| Applicable Standards | JIS K2283; ASTM D445, D446; ISO 3104, 3105 |
| Temperature Control Method | PID control |
| Temperature Control Accuracy | Within ±0.01°C of set temperature |
Model Comparison
| Specification | 403 Series (Medium-Temperature) | 404 Series (High-Temperature) | 405 Series (Low-Temperature) |
|---|---|---|---|
| Representative Model(s) | 403-262 (5-Position) | 404-072 / 404-073 | 405RT-031M / 405RT-031L |
| Typical Application | Medium-temperature kinematic viscosity testing | High-temperature kinematic viscosity testing | Low-temperature kinematic viscosity testing |