Automatic Pour, Cloud, and Cold Filter Plugging Point Tester: RPCF-301CML / -302CML / -303CML / -304CML / -306CML

These models rapidly and automatically carry out the pour point, cloud point, and cold filter plugging point test procedures prescribed in the applicable standards: ASTM D97, ISO 3016, and JIS K2269 for pour point; ASTM D2500, ISO 3015, and JIS K2269 for cloud point; and ASTM D6371, IP 309, and JIS K2288 for cold filter plugging point.

Rigo Automatic Pour, Cloud, and Cold Filter Plugging Point Tester: RPCF-301CML / -302CML / -303CML / -304CML / -306CML — Pour Point, Cloud Point & CFPP Testers

Manufacturer: Rigo — Japan

Overview

These models rapidly and automatically carry out the pour point, cloud point, and cold filter plugging point test procedures prescribed in the applicable standards: ASTM D97, ISO 3016, and JIS K2269 for pour point; ASTM D2500, ISO 3015, and JIS K2269 for cloud point; and ASTM D6371, IP 309, and JIS K2288 for cold filter plugging point. The apparatus consists of a cooling unit, which incorporates a cooling bath and two refrigerators, and a measuring unit built around a compact test bath of special metal construction. For pour point measurement, the test bath itself tilts and moves back and forth, testing the sample without disturbing its surface so that delicate pour point shifts caused by viscosity change or pour-point-depressant dosing can still be detected. Cloud point is measured with a photo-sensor and glass-fiber light guides that continuously track the temperature at which wax becomes visible at the bottom of the sample-filled test tube. The RPCF-301CML to RPCF-303CML configurations provide one, two, or three test positions, while four- and six-position versions are also available.

Cold Filter Plugging Point Detection

CFPP detection uses a clamp-type photo-sensor assembly to monitor the sample as it is drawn into a pipette. An upper photo-sensor detects the sample surface and determines the suction time, while a lower photo-sensor detects whether the surface has passed a reference point and determines the fall time. If the sample has not been drawn up to the pipette meniscus within 60 seconds of suction by the built-in vacuum unit, the instrument reports that temperature as the CFPP value.

Reverse CFPP Detection

The instrument also monitors whether a sample that was drawn up normally fails to return to the test tube within a set time; if it does not, that temperature is likewise reported as a CFPP value. This reverse-detection function protects against false results when a sample becomes too viscous to flow back through the filter, which is one of the practical failure modes of the standard CFPP procedure.

Common Specifications

SpecificationRPCF-301CML / -302CML / -303CML / -304CML / -306CML
Applicable standards — pour pointASTM D97 / ISO 3016 / JIS K2269
Applicable standards — cloud pointASTM D2500 / ISO 3015 / JIS K2269
Applicable standards — CFPPASTM D6371 / IP 309 / JIS K2288
Temperature range45 to -60°C (measuring unit)
Temperature detectionPlatinum resistance thermometer (Pt 100Ω)
Pour point detectionPhoto-sensor
Cloud point detectionPhoto-sensor via light guides
CFPP detectionPhoto-sensor
Measuring range45°C to -60.0°C (varies with ambient conditions)
Setting4.3-inch (54 x 95 mm) TFT touch panel
Measuring pitch — pour point1, 2.5, or 3°C, selectable
Measuring pitch — cloud pointStepwise, sequential detection
Measuring pitch — CFPP1°C, selectable
Data outputImpact dot printer; RS232C interface (D-sub 9, male)
Bath (jacket)Copper, 0.1 L capacity
Programmed temperatures — pour pointAutomatically rotated through 8 steps: +48, +25, +7, 0, -17.5, -34, -52.5, -70°C
Programmed temperatures — cloud pointAutomatically rotated through 6 steps: +48, 0, -17.5, -34, -52.5, -70°C
Programmed temperatures — CFPPAutomatically rotated through 4 steps: +53, -34, -51, -67°C
Temperature controlProportional control and heater On/Off
Accuracy of temperature control±0.5°C at each step
Heater100 W per test unit
Cooling unit temperature range0 to -70°C
Cooling bathStainless steel dewar vessel
Recommended coolantMethyl alcohol only
Refrigerator400 W x 2
Refrigeration systemAir-cooled, air-tight dual refrigeration system
RefrigerantR404A (280 g), TP5R3 (110 g)
Vacuum unit — water tank5 L
Vacuum unit — vacuum reservoir5 L
Vacuum unit — U-tube manometer1.96 kPa (200 mm aqu.)
Vacuum unit — air flow meter0 to 500 mL/min., with needle valve
Power requirementsSingle-phase 100V AC, 50/60Hz, 2.0kW

Model Comparison

SpecificationRPCF-301CML (1 unit)RPCF-302CML (2 units)RPCF-303CML (3 units)
No. of test positions123
Cooling bath capacity6 L6 L10 L
Dimensions (W x D x H, mm)Approx. 450 x 910 x 1,400Approx. 750 x 530 x 1,400Approx. 1,050 x 530 x 1,400
Approx. weight100 kg150 kg180 kg