Kinematic Viscometer: SVM 2001, SVM 3001, and SVM 4001

The SVM kinematic viscometer turns complexity into simplicity. Designed as a true all-in-one powerhouse, this automatic kinematic viscometer delivers much more than just viscosity: kinematic and dynamic viscosity, density, viscosity index, cloud point, freeze point, and more – all at the push of a button.

Anton Paar Kinematic Viscometer: SVM 2001, SVM 3001, and SVM 4001 — Viscometers

Manufacturer: Anton Paar — Austria

Overview

The SVM kinematic viscometer turns complexity into simplicity. Designed as a true all-in-one powerhouse, this automatic kinematic viscometer delivers much more than just viscosity: kinematic and dynamic viscosity, density, viscosity index, cloud point, freeze point, and more – all at the push of a button. It handles a wide temperature range effortlessly, using integrated Peltier technology, eliminating the hassle of liquid baths. Trusted worldwide, SVM meets over 50 international standards. Independent ASTM studies show it not only matches but often outperforms D445. Whatever your sample, wherever your lab, the SVM kinematic viscometer is your number one choice.

The Most Flexible Kinematic Viscometer

  • Multiple parameters (viscosity, density, viscosity index, API, cloud point, freeze point, and more)
  • 0.2 cSt to 30,000 cSt range – measure everything from jet fuel to wax
  • No capillary change required
  • -60 °C to +135 °C temperature range (SVM 3001)
  • Temperature change of up to 20 °C/min (SVM 3001 and 3001 Cold Properties)

Stay Compliant and Benefit from Bias Correction

  • D7042 is a global standard alternative to D445
  • Dual reporting: D7042 and D445 via bias correction
  • Complies with ASTM D396, D975, D1655, and 50+ other standards
  • ASTM D4052-compliant density included with SVM 3001 and up

Save Time with Our Automatic Kinematic Viscometers

  • 150 % higher throughput compared to manual methods
  • Up to 33 determinations per hour
  • Temperature equilibration in one minute or less
  • Faster results to avoid out-of-spec production

Improve Safety for Lab and Operator

  • Metal cell: No more glass breakage
  • Peltier thermostatting for fast temperature control
  • Reduced exposure to hazardous solvents
  • Safer operation: No flammable bath liquids

Minimal Sample, Solvent, and Energy Consumption

  • Analysis with just 5 mL sample and 6 mL solvent
  • Low energy consumption (max. 250 W)
  • Two-minute cleaning, 30-minute maintenance
  • 50 % less effort for QC documentation
  • No external PC or software needed

Digital Data Handling and Automation

  • Digital data recording and storage for reliable traceability
  • Automatic calculations for error-free measurements
  • Compatible with AP Connect for digital data management
  • Compatible with heated and non-heated sample changers
  • Automated filling and cleaning – even overnight

Models

Kinematic Viscometer: SVM is available in 4 models: SVM 2001, SVM 3001, SVM 3001 Cold Properties, SVM 4001.

SVM 2001

Kinematic viscosity at any temperature from 15 °C and 100 °C.

SVM 3001

Industry-proven kinematic viscometer and density meter.

SVM 3001 Cold Properties

Freeze point, cloud point, viscosity, and density in one run.

SVM 4001

Fastest viscosity index using two cells (min. 2.5 minutes).

Specifications

SpecificationSVM 2001SVM 3001SVM 3001 Cold PropertiesSVM 4001
PatentsAT516058 (B1), US10036695 (B2), CN105424556, EP2995928 (B1)AT516058 (B1), US10036695 (B2), CN105424556, EP2995928 (B1) AT516302 (B1), CN105628550AT516058 (B1), US10036695 (B2), CN105424556, EP2995928 (B1) AT516302 (B1), CN105628550AT516058 (B1), US10036695 (B2), CN105424556, EP2995928 (B1) AT516302 (B1), CN105628550
Test MethodsASTM D7042, D445 bias-corrected, ISO 23581, ASTM D4052 (optional)ASTM D7042, D445 bias-corrected, ISO 23581, ASTM D4052, ISO 12185ASTM D7042, D445 bias-corrected, ISO 23581, ASTM D4052, ISO 12185,
ASTM D2500 equiv. or better, ASTM D8630
ASTM D7042, D445 bias-corrected, ISO 23581, ASTM D4052, ISO 12185
Measuring Range
Viscosity0.2 mm²/s to 30,000 mm²/s *
Density0 g/cm³ to 3 g/cm³
Temperature+15 °C to +100 °C-60 °C to +135 °C-60 °C to +100 °C+15 °C to +100°C
Precision
Viscosity Repeatability and Reproducibility0.1 % and 0.35 %
Density Repeatability and Reproducibility0.0002 g/cm³
(0.00005 g/cm² with ASTM D4052 option) and 0.0005 g/cm³
(0.0001 g/cm² with ASTM D4052 option)
0.00005 g/cm³ and 0.0001 g/cm³0.00005 g/cm³ and 0.0001 g/cm³0.00005 g/cm³ and 0.0001 g/cm³
Cloud/Freeze Point Repeatability and Reproducibility--<0.5 °C / 0.4 °C * and
<2.5 °C / 1.1 °C *
-
Temperature Repeatability0.005 °C
Temperature Reproducibility0.03 °C from +15 °C to +100 °C0.03 °C from +15 °C to +100 °C0.03 °C from +15 °C to +100 °C0.03 °C from +15 °C to +100 °C
Performance
Sample Volume Min. / Typical1.5 mL / 5 mL1.5 mL / 5 mL1.5 mL / 5 mL2.5 mL / 6 mL
Solvent Volume Min. / Typical1.5 mL / 6 mL1.5 mL / 6 mL1.5 mL / 6 mL2.5 mL / 10 mL
Max. Sample Throughput33 samples per hour33 samples per hour30 samples per hour24 samples per hour
Features
Optional UpgradesAutomatic VI determination ASTM D4052-compliant density measurementChemical upgrade kit--
Modularity with Abbemat Refractometers 5001, 5101, 5201, 7001, and 7201
AccessoriesMagnetic particle trap (MPT), hot filling attachment (HFA)Magnetic particle trap (MPT), hot filling attachment (HFA)Magnetic particle trap (MPT)Magnetic particle trap (MPT)
AutomationOptional sample changer + High-Throughput Platform HTV
Technical Data
Data Memory1,000 measurement results
HID (Human Interface Device)10.4" touchscreen, optional keyboard, mouse, and 2D bar code reader
Interfaces4 x USB (2.0 full speed), 1 x Ethernet (100 Mbit), 1 x CAN bus, 1 x RS-232, 1 x VGA
Power SupplyAC 100 V to 240 V, 50 Hz to 60 Hz, 250 VA max.
Ambient Conditions15 °C to 35 °C, max. 80 % r.h. non-condensing
Net Weight in kg15.9 kg17.6 kg18.0 kg17.8 kg
Dimensions (W x D x H)33 cm x 51 cm x 23.1 cm
TrademarksSVM (13411996), FillingCheck (6834725), Abbemat (1084545)
Notes* Viscosity range with chemical upgrade kit from 1 mPa·s to 10,000 mPa·s
** Verified at the support points of the factory adjustment range or at the calibration correction points. Uncertainty of the standards not included.
***At -47 °C according to ASTM D8630

Interested in this model? Let's talk specifics.

Request a formal quotation or a detailed technical discussion — our engineers respond within one business day.

Request a Quote