Dual Wavelength Compact Raman Spectrometer: Cora 5001 Direct

The Cora 5001 Direct Raman analyzer is a compact Raman spectrometer for substance identification using their unique chemical fingerprints within seconds.

Anton Paar Dual Wavelength Compact Raman Spectrometer: Cora 5001 Direct — Raman Spectrometers

Manufacturer: Anton Paar — Austria

Overview

The Cora 5001 Direct Raman analyzer is a compact Raman spectrometer for substance identification using their unique chemical fingerprints within seconds. It also enables the characterization of samples and the quantification of specific components, providing comprehensive analytical insights. The Direct model, equipped with a sample compartment, analyzes samples within a closed environment and is certified as laser class 1, ensuring ultra-safe operation. This model features a guided analysis procedure, making it easy to use with minimal training.

User Guidance and Laser Class 1 Safety

Handling the Cora 5001 Raman spectrometers can be learned within minutes, allowing users to perform Raman spectroscopy measurements safely. In contrast to many handheld instruments, the Cora 5001 Direct Raman instruments are extra-safe due to their laser Class 1 specification. The laser can only be activated if the measuring chamber is closed and therefore poses no threat to people working in close vicinity to the device.

One Compact Raman Spectrometer, Multiple Samples

Do you work with challenging (fluorescing) substances or many different samples? To cover the widest range of samples and account for possible fluorescence, the dual wavelength models provide you with two different excitation wavelengths in one instrument. Each wavelength comes in its own independent optical spectrometer system. Hop from one wavelength to the other at the click of a button without alignment or recalibration and analyze the whole range of substances.

Pharma Compliance – with the Anton Paar Spectroscopy Suite

The Anton Paar Spectroscopy Suite takes the complexity out of Raman analysis in the regulated environment. Workflows guide the operator in daily analysis. Lab managers receive assistance in setting up methods and managing reference databases. Comprehensive signing and versioning provide traceability at all times. Audit trail commenting and search functionality are a huge help in audits. And all data is securely retained in an SQL data base.

Ideal for Teaching

The Direct model is certified as laser class 1, ensuring ultra-safe operation. Its guided analysis procedure makes it ideal for educational and teaching purposes, allowing students to perform accurate and easy-to-understand experiments with minimal training. This approach also makes it a valuable tool for introducing Raman spectroscopy in educational settings.

Autofocus – the Strongest Signal for Reproducible Results

Manual focusing onto thin or opaque samples with a weak Raman signal can be tricky. The Cora autofocus feature takes all the complexity out of the measuring routine. It automatically finds the spot with the best Raman signal within seconds so you don't have to worry about it. This ensures reproducibility and makes the analysis independent of the user.

Models

Dual Wavelength Compact Raman Spectrometer: Cora 5001 Direct is available in 2 models: Cora 5001 Direct Standard, Cora 5001 Direct Pharma.

Cora 5001 Direct Standard

Safe: Laser class 1 for unsurpassed laser safety.

Cora 5001 Direct Pharma

Powerful: Daily analysis, method creation, and reference library management.

Specifications

SpecificationSingle-wavelength 532 nmSingle-wavelength 785 nmSingle-wavelength 1064 nmDual-wavelength 532 nm and 785 nmDual-wavelength 532 nm and 1064 nmDual-wavelength 785 nm and 1064 nm
Optical Specifications
Excitation Wavelength532 nm785 nm1064 nm532 nm and 785 nm532 nm and 1064 nm785 nm and 1064 nm
Spectral Range200 cm⁻¹ to 3500 cm⁻¹100 cm⁻¹ to 2300 cm⁻¹100 cm⁻¹ to 2300 cm⁻¹200 cm⁻¹ to 3500 cm⁻¹ for 532 nm
100 cm⁻¹ to 2300 cm⁻¹ for 785 nm
200 cm⁻¹ to 3500 cm⁻¹ for 532 nm
100 cm⁻¹ to 2300 cm⁻¹ for 1064 nm
100 cm⁻¹ to 2300 cm⁻¹ for 785 nm and 1064 nm
Resolution (according to ASTM E2529)9 cm⁻¹ to 12 cm⁻¹6 cm⁻¹ to 9 cm⁻¹12 cm⁻¹ to 17 cm⁻¹9 cm⁻¹ to 12 cm⁻¹ for 532 nm
6 cm⁻¹ to 9 cm⁻¹ for 785 nm
9 cm⁻¹ to 12 cm⁻¹ for 532 nm
12 cm⁻¹ to 17 cm⁻¹ for 1064 nm
6 cm⁻¹ to 9 cm⁻¹ for 785 nm
12 cm⁻¹ to 17 cm⁻¹ for 1064 nm
Laser Power50 mW**0 mW to 450 mW*, adjustable0 mW to 450 mW*, adjustable50 mW* for 532 nm
0 mW to 450 mW* for 785 nm
50 mW* for 532 nm
0 mW to 450 mW* for 1064 nm
0 mW to 450 mW* for 785 nm and 1064 nm
Spectrographf/2; Transmission volume phase grating (VPG)
Integration Time0.005 s to 600 s0.005 s to 600 s0.001 s to 20 s0.005 s to 600 s for 532 nm and 785 nm0.005 s to 600 s for 532 nm
0.001 s to 20 s for 1064 nm
0.005 s to 600 s for 785 nm
0.001 s to 20 s for 1064 nm
Wavelength CalibrationAutomatic via software
Detector Array2048 px CCD2048 px CCD256 px InGaAs2048 px CCD for 532 nm and 785 nm2048 px CCD for 532 nm
256 px InGaAs for 1064 nm
2048 px CCD for 785 nm
256 px InGaAs for 1064 nm
Laser Class1 for Direct model
3B for Fiber model
Physical Specifications
Dimensions (D x W x H)355 mm x 384 mm x 168 mm (14.0 in x 15.1 in x 6.6 in)
Weight9.8 kg
Operating Range10 °C to 35 °C (non-condensing)
Fiber Probe DimensionsCable length: 1.50 m
Battery (optional)Lithium-ion
Battery Run Time>1.5 h
Power Supply InputLine power supply input: 115/230 V AC, 50/60 Hz
Car power adapter input: 9 V to 32 V DC
Power ConsumptionIn-line power supply input: max. 100 VA
DC input: typical 30 VA (60 VA when optional battery is charged)
Additional Specifications
Display10-inch touch screen
Data Ports4 x USB 2.0, 1 x Ethernet, 1 x CAN out and 1 x USB to PC
Data Export Formats.csv, .txt, .png, .spc,. aps, .pdf
Internal Storage8 GB
Wireless ConnectivityWi-Fi stick (optional)
Spectral LibrariesFactory library, user-built, third-party options