Coriolis Flow Meter: L-Cor 8000 Series

The L-Cor 8000 series Coriolis flow meter provides a complete solution for mass flow, density, and concentration measurement. From microdosing at 0.4 grams per minute to high-volume custody transfer, one meter family covers any industry or scale.

Anton Paar Coriolis Flow Meter: L-Cor 8000 Series — Flow Meters

Manufacturer: Anton Paar — Austria

Overview

The L-Cor 8000 series Coriolis flow meter provides a complete solution for mass flow, density, and concentration measurement. The sensor series delivers accurate flow, density, and concentration measurement across the most demanding industries and process conditions including extreme temperatures, high pressures, and high-viscosity media. With expert guidance and outstanding customer service, we help you find the perfect solution for your process and support you throughout the entire product lifecycle.

From Micrograms to Megatons: One Meter for Any Industry or Scale

From microdosing applications such as fragrance handling at 0.4 grams per minute to high-volume custody transfer measurement up to 1,400 metric tons per hour, the L-Cor 8000 series delivers accurate flow, density, and concentration measurement across the full measurement spectrum.

A Coriolis Flow Meter Engineered for Extremes

Built for durability and a long service life even in the toughest environments, the Coriolis flow meter sensors cover temperature spans of up to 400 °C, withstand maximum process pressures of more than 400 bar, and are certified for hazardous areas. Cryogenic variants are capable of measuring temperatures as low as -200 °C, with high-temperature variants enabling flow monitoring up to + 350 °C. Even viscous media of 10,000 mPa·s and beyond pose no challenge. A range of wetted material options, including stainless steel and Alloy C, ensures maximum compatibility with your process media.

Reliable Gas Flow Monitoring

The L-Cor 8000 Coriolis flow meter is ideally suited for precise flow measurement of dry gaseous media, delivering high accuracy independent of gas type, temperature, or process pressure. Its robust and maintenance-free design ensures consistent and reliable performance, even under demanding process conditions. High measurement precision enables tight process control, making it an excellent choice for beverage and chemical processing, as well as energy and gas distribution.

Certified for Custody Transfer

Anton Paar’s Coriolis flow meters enable traceable measurements in custody transfer applications. Full compliance with standards such as OIML R 117-1, MC, as well as certification according to ISO/IEC 17025, ensures the accuracy and integrity required for fiscal metering across industries.

Expert Support You Can Rely on

Anton Paar is well known for its extensive application expertise, world-class customer support, and comprehensive after-sales service, including a standard three-year warranty on all meters. From day one, you gain access to a team with extensive knowledge and experience in flow, density, and concentration monitoring across a wide range of industries and applications. Backed by a global presence and more than 100 years of measurement experience, we deliver tailored solutions that meet your specific requirements.

Specifications

SpecificationL-Cor 8000 (1/4")L-Cor 8000 (3/8")L-Cor 8000 (3/8" to 3")L-Cor 8000 (4" to 6")L-Cor 8100L-Cor 8200L-Cor 8300
Flowrate0.024 kg/h to 9 kg/h0.72 kg/h to 72 kg/h3.6 kg/h to 120,000 kg/h3420 kg/h to 700,000 kg/h108 kg/h to 342,000 kg/h108 kg/h to 700,000 kg/h24 kg/h to 2,550 kg/h
Flow Accuracy Liquid± 0.2%± 0.1%± 0.1%± 0.1%± 0.1% ± ZS± 0.1%*± 0.2% ± ZS
Flow Repeatability Liquid± 0.05%± 0.05%± 0.05%± 0.05%± 0.05% ± ZS± 0.05%± 0.1% ± ½ ZS
Flow Accuracy Gas± 0.5% ± ZS± 0.5% ± ZS± 0.5% ± ZS± 0.5% ± ZS-± 0.5% ± ZS± 0.5% ± ZS
Flow Repeatability Gas± 0.25% ± ½ ZS± 0.25% ± ½ ZS± 0.25% ± ½ ZS± 0.25% ± ½ ZS-± 0.25% ± ½ ZS± 0.25% ± ½ ZS
Density Range300 kg/m³ to 2,000 kg/m³
Density Accuracy± 3 kg/m³± 0.5 kg/m³± 0.5 kg/m³± 0.5 kg/m³± 3 kg/m³± 0.5 kg/m³± 4 kg/m³
Nominal Diameter1/4"3/8"3/8" to 3"4" to 6"1" to 6"1" to 6"1/2"
Ambient Temperature- 40 °C to +55 °C
Process Temperature- 200 °C to +200 °C- 200 °C to +200 °C- 200 °C to +200 °C- 200 °C to +200 °C-40 °C to +350 °C-200 °C to +50 °C-200 °C to +200 °C
Process Pressure Absolute150 bar (at 20 °C)According to flange specificationAccording to flange specificationAccording to flange specificationAccording to flange specificationAccording to flange specificationMax. 430 bar (at 20°C)
Process ConnectionThread R 1/4ASME B16.5 Class 150, 300, 600
EN 1092-1 PN40
Tri-clamp ISO 2852
Thread R/Rc
ASME B16.5 Class 150, 300, 600
EN 1092-1 PN40
Tri-clamp ISO 2852
Thread R/Rc
ASME B16.5 Class 150, 300, 600
EN 1092-1 PN16, 40
ASME B16.5 Class 150, 300, 600
EN 1092-1 PN16, 40
ASME B16.5 Class 150, 300, 600
EN 1092-1 PN16, 40
Rc 3/8
Rc 3/4
Wetted Parts1.4404 (316L)1.4404 (316L)
Alloy C-22
1.4404 (316L)
Alloy C-22
1.4404 (316L)1.4404 (316L)1.4404 (316L)1.4404 (316L)
Approvals for Potentially Explosive AtmospheresATEX, IECEx, CSA (C-US), NEPSI (CCC)
Outputs2x analog, 2x pulse (frequency), 1x status output
Inputs1x status input
Digital CommunicationBell 202, Modbus RTU (RS-485), Profibus PA, Fieldbus
Transmitter VersionIntegrated, separately mounted, mounted in control cabinet
CertificationsOIML R117-1:2019 (according to WELMEC 8.8 & 7.2)
Notes* ± ZS is applied for flow rates below 5 % of the maximum measuring range. Accuracy valid at reference conditions. ZS = Zero stability error = (Zero stability)/(Flowrate at the moment) x100%