Electrokinetic Analyzer for Solid Surface Analysis: SurPASS 3

The SurPASS 3 series features fully automated zeta potential analysis of macroscopic solids under real-life conditions. As electrokinetic analyzers, they employ the classic streaming potential and streaming current method for a direct analysis of the surface zeta potential.

Anton Paar Electrokinetic Analyzer for Solid Surface Analysis: SurPASS 3 — Surface Charge and Zeta Potential Analyzers

Manufacturer: Anton Paar — Austria

Overview

The SurPASS 3 series features fully automated zeta potential analysis of macroscopic solids under real-life conditions. As electrokinetic analyzers, they employ the classic streaming potential and streaming current method for a direct analysis of the surface zeta potential. The zeta potential is related to the surface charge at a solid/liquid interface and is a key parameter for understanding surface properties and developing new specialized materials.

Solid Surface Charge Analysis Made Easy

The SurPASS 3 series allows for direct analysis of the zeta potential at the solid/liquid interface by means of streaming potential and streaming current measurement. This gives access to the full range of zeta potential of technical materials down to a few millivolts at unprecedented reliability and reproducibility. Gain instant access to information on surface charge without the need for sophisticated evaluation or expert knowledge.

Measuring Solutions from Tiny Particles to Large Wafers

The wide range of SurPASS 3 measuring cells covers it all: Elaborate measuring cells accommodate samples of any geometry ranging from powders and fibers to planar solids. Sample-specific measuring cells for contact lenses, hollow fiber membranes, flexible tubings, syringes, and vials open up surface charge analysis on samples with complex geometries. The “plug in and start” functionality allows for a quick exchange of measuring cells. The software automatically recognizes the measuring cells and displays the zeta potential.

Fully Automated Measurements in Less than Two Minutes

The intuitive SurPASS 3 software guides you through the measurement and displays all key parameters in real-time. The SurPASS 3 series provides zeta potential results in less than two minutes for maximized sample throughput. SurPASS 3 allows you to study pH dependences of zeta potential fully automatically and reveals the isoelectric point for a deep understanding of your sample’s chemistry. Liquid-on-solid surface adsorption kinetics can also be followed in real-time on model surfaces and on your actual sample.

Modular Setup Tailored to Your Needs

The SurPASS 3 series is just as versatile as your applications. Dedicated solutions are available for membrane applications, biomaterials, cosmetics, detergents, and semiconductors. Whether you are working on porous materials, such as membranes, or non-porous films and plates, particles >25 µm, granular material, fibers, or materials which swell strongly or are conductive: there are no restrictions. The modular setup of the instrument and measuring cells allows you to easily extend your zeta potential analysis to cover tomorrow’s needs.

Models

Electrokinetic Analyzer for Solid Surface Analysis: SurPASS 3 is available in 2 models: SurPASS 3 Standard, SurPASS 3 Eco.

SurPASS 3 Standard

High-end electrokinetic analyzer for solid surface analysis.

SurPASS 3 Eco

Entry-level electrokinetic analyzer for routine surface analysis.

Specifications

SpecificationSurPASS 3SurPASS 3 Eco
Measuring Range
Streaming Potential±2000 mV ± (0.2 % + 4 μV)
Streaming Current±2 mA ± (0.2 % + 1 pA)
Cell Resistance5 Ω to 20 MΩ ± (2 % + 0.5 Ω)
Pressure Measurement3500 mbar ± (0.2 % + 0.5 mbar)
External pressure supply (compressed N₂) is required for differential pressure > 1200 mbar
1200 mbar ± (0.2 % + 0.5 mbar)
pH ValuepH 2 to pH 12
Conductivity0.1 mS/m to 1000 mS/m
Temperature20 °C to 40 °C
Temperature control option is available
Sample Size Requirements
Porous Films, Foils, or PlatesRectangular-shaped: 20 mm x 10 mm (max. thickness: 2 mm )
Disk-shaped: 14 mm or 15 mm in diameter (max. thickness: 2 mm)
Non-porous Films, Foils, or PlatesRectangular-shaped: 20 mm x 10 mm (max. thickness: 2 mm) or
min. 35 mm x 15 mm (max. thickness: 40 mm)
Disk-shaped: 14 mm or 15 mm in diameter (max. thickness: 2 mm) or
min. 17 mm in diameter (max. thickness: 40 mm)
ParticlesParticle size: min. 25 μm
FibersMin. 100 mg
FabricsMin. 30 mm x 30 mm
Hollow Fiber MembranesLength: min. 170 mm
Ceramic MembranesFlat sheet: 14 mm in diameter
Single channel: outer diameter 10 mm or 13 mm
Multichannel: outer diameter 25 mm or 30 mm
Cylindrical CoresHeight: max. 4 inch
Diameter: 1 inch
Flexible TubingLength: min. 100 mm
Outer diameter: 0.7 mm to 6 mm
Pre-filled SyringesSyringe barrel “1.0 mL long” (ISO 11040-4)
Vials2R/4R vials (ISO format), outer diameter 16 mm
Technical Requirements
Mains SupplyAC 115 to 230 V, 50 to 60 Hz, 200 VA
Dimensions600 mm x 432 mm x 245 mm (D x W x H)
Footprint: 612 mm x 536 mm (D x W)
Clearance: 360 mm
Weight26 kg24 kg
SoftwareMicrosoft Windows® 7 32/64 bit with SP1 or later is required. Windows 7 Starter is not supported. Microsoft Windows® 8 32/64 bit Microsoft Windows® Server 2008/2008 R2 32/64 bit with Service Pack 2 or higher is required for Windows Server 2008 Microsoft Windows® 10 32/64 bit
Intel® Core™ i3 CPU
4 GB RAM (depends on operating system)
20 GB free disk space
1 free USB port
Screen resolution of at least 1024 x 768 at True Color (32 bit)

Interested in this model? Let's talk specifics.

Request a formal quotation or a detailed technical discussion — our engineers respond within one business day.

Request a Quote

← Surface Charge and Zeta Potential Analyzers